SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Extended search

Träfflista för sökning "db:Swepub ;pers:(Persson Anders);pers:(Carlhäll Carljohan)"

Search: db:Swepub > Persson Anders > Carlhäll Carljohan

  • Result 1-10 of 11
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Bäck, Sophia, et al. (author)
  • Assessment of transmitral and left atrial appendage flow rate from cardiac 4D-CT
  • 2023
  • In: Communications Medicine. - : Springer Nature. - 2730-664X. ; 3:1
  • Journal article (peer-reviewed)abstract
    • Plain language summaryAssessing the blood flow inside the heart is important in diagnosis and treatment of various cardiovascular diseases, such as atrial fibrillation or heart failure. We developed a method to accurately track the motion of the heart walls over the course of a heartbeat in three-dimensional Computed Tomography (CT) images. Based on the motion, we calculated the amount of blood passing through the mitral valve and the left atrial appendage orifice, which are markers used in the diagnostic of heart failure and assessment of stroke risk in atrial fibrillation. The results agreed well with measurements from 4D flow MRI, an imaging technique that measures blood velocities. Our method could broaden the use of CT and make additional exams redundant. It can even be used to calculate the blood flow inside the heart. BackgroundCardiac time-resolved CT (4D-CT) acquisitions provide high quality anatomical images of the heart. However, some cardiac diseases require assessment of blood flow in the heart. Diastolic dysfunction, for instance, is diagnosed by measuring the flow through the mitral valve (MV), while in atrial fibrillation, the flow through the left atrial appendage (LAA) indicates the risk for thrombus formation. Accurate validated techniques to extract this information from 4D-CT have been lacking, however.MethodsTo measure the flow rate though the MV and the LAA from 4D-CT, we developed a motion tracking algorithm that performs a nonrigid deformation of the surface separating the blood pool from the myocardium. To improve the tracking of the LAA, this region was deformed separately from the left atrium and left ventricle. We compared the CT based flow with 4D flow and short axis MRI data from the same individual in 9 patients.ResultsFor the mitral valve flow, good agreement was found for the time span between the early and late diastolic peak flow (bias: <0.1 s). The ventricular stroke volume is similar compared to short-axis MRI (bias 3 ml). There are larger differences in the diastolic peak flow rates, with a larger bias for the early flow rate than the late flow rate. The peak LAA outflow rate measured with both modalities matches well (bias: -6 ml/s).ConclusionsOverall, the developed algorithm provides accurate tracking of dynamic cardiac geometries resulting in similar flow rates at the MV and LAA compared to 4D flow MRI. Back et al. describe a motion tracking algorithm to measure the flow rate through the mitral valve (MV) and the left atrial appendage (LAA) from 4D-CT data. The developed algorithm provided accurate tracking of dynamic cardiac geometries resulting in similar flow rates at the MV and LAA to those measured by 4D flow MRI.
  •  
2.
  • Bäck, Sophia, et al. (author)
  • Comprehensive left atrial flow component analysis reveals abnormal flow patterns in paroxysmal atrial fibrillation
  • 2024
  • In: American Journal of Physiology. Heart and Circulatory Physiology. - : AMER PHYSIOLOGICAL SOC. - 0363-6135 .- 1522-1539. ; 326:3, s. H511-H521
  • Journal article (peer-reviewed)abstract
    • Left atrial (LA) blood flow plays an important role in diseases such as atrial fibrillation (AF) and atrial cardiomyopathy since alterations in the blood flow might lead to thrombus formation and stroke. Using traditional techniques, such as echocardiography, atrial flow velocities can be measured at the pulmonary veins and the mitral valve, but a comprehensive understanding of the three-dimensional atrial flow field is missing. Previously, ventricular flow has been analyzed using flow component analysis, revealing new insights into ventricular flow and function. Thus, the aim of this project was to develop a comprehensive flow component analysis method for the LA and explore its utility in 21 patients with paroxysmal atrial fibrillation compared with a control group of 8 participants. The flow field was derived from time-resolved CT acquired during sinus rhythm using computational fluid dynamics. Flow components were computed from particle tracking. We identified six atrial flow components: conduit, reservoir, delayed ejection, retained inflow, residual volume, and pulmonary vein backflow. It was shown that conduit flow, defined as blood entering and leaving the LA within the same diastolic phase, exists in most subjects. Although the volume of conduit and reservoir is similar in patients with paroxysmal AF in sinus rhythm and controls, the volume of the other components is increased in paroxysmal AF. Comprehensive quantification of LA flow using flow component analysis makes atrial blood flow quantifiable, thus facilitating investigation of mechanisms underlying atrial dysfunction and can increase understanding of atrial blood flow in disease progression and stroke risk. NEW & NOTEWORTHY We developed a new comprehensive approach to atrial blood component analysis that includes both conduit flow and residual volume and compared the flow components of atrial fibrillation (AF) patients in sinus rhythm with controls. Conduit and reservoir flow were similar between the groups, whereas components with longer residence time in the left atrium were increased in the AF group. This could add to the pathophysiological understanding of atrial diseases and possibly clinical management.
  •  
3.
  •  
4.
  • Bäck, Sophia, et al. (author)
  • Elevated atrial blood stasis in paroxysmal atrial fibrillation during sinus rhythm: a patient-specific computational fluid dynamics study
  • 2023
  • In: Frontiers in Cardiovascular Medicine. - : FRONTIERS MEDIA SA. - 2297-055X. ; 10
  • Journal article (peer-reviewed)abstract
    • Introduction: Atrial fibrillation (AF) is associated with an increased risk of stroke, often caused by thrombi that form in the left atrium (LA), and especially in the left atrial appendage (LAA). The underlying mechanism is not fully understood but is thought to be related to stagnant blood flow, which might be present despite sinus rhythm. However, measuring blood flow and stasis in the LAA is challenging due to its small size and low velocities. We aimed to compare the blood flow and stasis in the left atrium of paroxysmal AF patients with controls using computational fluid dynamics (CFD) simulations.Methods : The CFD simulations were based on time-resolved computed tomography including the patient-specific cardiac motion. The pipeline allowed for analysis of 21 patients with paroxysmal AF and 8 controls. Stasis was estimated by computing the blood residence time.Results and Discussion: Residence time was elevated in the AF group (p < 0.001). Linear regression analysis revealed that stasis was strongest associated with LA ejection ratio (p < 0.001, R-2 = 0.68) and the ratio of LA volume and left ventricular stroke volume (p < 0.001, R-2 = 0.81). Stroke risk due to LA thrombi could already be elevated in AF patients during sinus rhythm. In the future, patient specific CFD simulations may add to the assessment of this risk and support diagnosis and treatment.
  •  
5.
  • Ekblom Bak, Elin, 1981-, et al. (author)
  • Accelerometer derived physical activity and subclinical coronary and carotid atherosclerosis : cross-sectional analyses in 22 703 middle-aged men and women in the SCAPIS study
  • 2023
  • In: BMJ Open. - : BMJ Publishing Group Ltd. - 2044-6055. ; 13:11
  • Journal article (peer-reviewed)abstract
    • OBJECTIVES: The aim included investigation of the associations between sedentary (SED), low-intensity physical activity (LIPA), moderate-to-vigorous intensity PA (MVPA) and the prevalence of subclinical atherosclerosis in both coronaries and carotids and the estimated difference in prevalence by theoretical reallocation of time in different PA behaviours.DESIGN: Cross-sectional.SETTING: Multisite study at university hospitals.PARTICIPANTS: A total of 22 670 participants without cardiovascular disease (51% women, 57.4 years, SD 4.3) from the population-based Swedish CArdioPulmonary bioImage study were included. SED, LIPA and MVPA were assessed by hip-worn accelerometer.PRIMARY AND SECONDARY OUTCOMES: Any and significant subclinical coronary atherosclerosis (CA), Coronary Artery Calcium Score (CACS) and carotid atherosclerosis (CarA) were derived from imaging data from coronary CT angiography and carotid ultrasound.RESULTS: High daily SED (>70% ≈10.5 hours/day) associated with a higher OR 1.44 (95% CI 1.09 to 1.91), for significant CA, and with lower OR 0.77 (95% CI 0.63 to 0.95), for significant CarA. High LIPA (>55% ≈8 hours/day) associated with lower OR for significant CA 0.70 (95% CI 0.51 to 0.96), and CACS, 0.71 (95% CI 0.51 to 0.97), but with higher OR for CarA 1.41 (95% CI 1.12 to 1.76). MVPA above reference level, >2% ≈20 min/day, associated with lower OR for significant CA (OR range 0.61-0.67), CACS (OR range 0.71-0.75) and CarA (OR range 0.72-0.79). Theoretical replacement of 30 min of SED into an equal amount of MVPA associated with lower OR for significant CA, especially in participants with high SED 0.84 (95% CI 0.76 to 0.96) or low MVPA 0.51 (0.36 to 0.73).CONCLUSIONS: MVPA was associated with a lower risk for significant atherosclerosis in both coronaries and carotids, while the association varied in strength and direction for SED and LIPA, respectively. If causal, clinical implications include avoiding high levels of daily SED and low levels of MVPA to reduce the risk of developing significant subclinical atherosclerosis.
  •  
6.
  • Lantz, Jonas, et al. (author)
  • Characterization of Cardiac Flow in Heart Disease Patients by CFD and 4D Flow MRI
  • 2017
  • In: Bulletin of the Amerian Physcial Society. - : American Physical Society.
  • Conference paper (peer-reviewed)abstract
    • In this study, cardiac blood flow was simulated using Computational Fluid Dynamics and compared to in vivo flow measurements by 4D Flow MRI. In total, nine patients with various heart diseases were studied. Geometry and heart wall motion for the simulations were obtained from clinical CT measurements, with 0.3x0.3x0.3 mm spatial resolution and 20 time frames covering one heartbeat. The CFD simulations included pulmonary veins, left atrium and ventricle, mitral and aortic valve, and ascending aorta. Mesh sizes were on the order of 6-16 million cells, depending on the size of the heart, in order to resolve both papillary muscles and trabeculae. The computed flow field agreed visually very well with 4D Flow MRI, with characteristic vortices and flow structures seen in both techniques. Regression analysis showed that peak flow rate as well as stroke volume had an excellent agreement for the two techniques. We demonstrated the feasibility, and more importantly, fidelity of cardiac flow simulations by comparing CFD results to in vivo measurements. Both qualitative and quantitative results agreed well with the 4D Flow MRI measurements. Also, the developed simulation methodology enables “what if” scenarios, such as optimization of valve replacement and other surgical procedures.
  •  
7.
  •  
8.
  • Lantz, Jonas, 1982-, et al. (author)
  • Impact of prosthetic mitral valve orientation on the ventricular flow field : Comparison using patient-specific computational fluid dynamics
  • 2021
  • In: Journal of Biomechanics. - : Elsevier Science Ltd. - 0021-9290 .- 1873-2380. ; 116
  • Journal article (peer-reviewed)abstract
    • Significant mitral valve regurgitation creates progressive adverse remodeling of the left ventricle (LV). Replacement of the failing valve with a prosthesis generally improves patient outcomes but leaves the patient with non-physiological intracardiac flow patterns that might contribute to their future risk of thrombus formation and embolism. It has been suggested that the angular orientation of the implanted valve might modify the postoperative distortion of the intraventricular flow field. In this study, we investigated the effect of prosthetic valve orientation on LV flow patterns by using heart geometry from a patient with LV dysfunction and a competent native mitral valve to calculate intracardiac flow fields with computational fluid dynamics (CFD). Results were validated using in vivo 4D Flow MRI. The computed flow fields were compared to calculations following virtual implantation of a mechanical heart valve oriented in four different angles to assess the effect of leaflet position. Flow patterns were visualized in longand short-axes and quantified with flow component analysis. In comparison to a native valve, valve implantation increased the proportion of the mitral inflow remaining in the basal region and further increased the residual volume in the apical area. Only slight changes due to valve orientation were observed. Using our numerical framework, we demonstrated quantitative changes in left ventricular blood flow due to prosthetic mitral replacement. This framework may be used to improve design of prosthetic heart valves and implantation procedures to minimize the potential for apical flow stasis, and potentially assist personalized treatment planning. (c) 2020 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
  •  
9.
  • Lantz, Jonas, 1982-, et al. (author)
  • Impact of Pulmonary Venous Inflow on Cardiac Flow Simulations : Comparison with In Vivo 4D Flow MRI
  • 2019
  • In: Annals of Biomedical Engineering. - : Springer-Verlag New York. - 0090-6964 .- 1573-9686. ; 47:2, s. 413-424
  • Journal article (peer-reviewed)abstract
    • Blood flow simulations are making their way into the clinic, and much attention is given to estimation of fractional flow reserve in coronary arteries. Intracardiac blood flow simulations also show promising results, and here the flow field is expected to depend on the pulmonary venous (PV) flow rates. In the absence of in vivo measurements, the distribution of the flow from the individual PVs is often unknown and typically assumed. Here, we performed intracardiac blood flow simulations based on time-resolved computed tomography on three patients, and investigated the effect of the distribution of PV flow rate on the flow field in the left atrium and ventricle. A design-of-experiment approach was used, where PV flow rates were varied in a systematic manner. In total 20 different simulations were performed per patient, and compared to in vivo 4D flow MRI measurements. Results were quantified by kinetic energy, mitral valve velocity profiles and root-mean-square errors of velocity. While large differences in atrial flow were found for varying PV inflow distributions, the effect on ventricular flow was negligible, due to a regularizing effect by mitral valve. Equal flow rate through all PVs most closely resembled in vivo measurements and is recommended in the absence of a priori knowledge.
  •  
10.
  • Lantz, Jonas, 1982-, et al. (author)
  • Intracardiac Flow at 4D CT : Comparison with 4D Flow MRI
  • 2018
  • In: Radiology. - Oak Brook, IL United States : Radiological Society of North America, Inc.. - 0033-8419 .- 1527-1315. ; 289:1, s. 51-58
  • Journal article (peer-reviewed)abstract
    • PurposeTo investigate four-dimensional (4D) flow CT for the assessment of intracardiac blood flow patterns as compared with 4D flow MRI.Materials and MethodsThis prospective study acquired coronary CT angiography and 4D flow MRI data between February and December 2016 in a cohort of 12 participants (age range, 36–74 years; mean age, 57 years; seven men [age range, 36–74 years; mean age, 57 years] and five women [age range, 52–73 years; mean age, 64 years]). Flow simulations based solely on CT-derived cardiac anatomy were assessed together with 4D flow MRI measurements. Flow patterns, flow rates, stroke volume, kinetic energy, and flow components were quantified for both techniques and were compared by using linear regression.ResultsCardiac flow patterns obtained by using 4D flow CT were qualitatively similar to 4D flow MRI measurements, as graded by three independent observers. The Cohen κ score was used to assess intraobserver variability (0.83, 0.79, and 0.70) and a paired Wilcoxon rank-sum test showed no significant change (P > .05) between gradings. Peak flow rate and stroke volumes between 4D flow MRI measurements and 4D flow CT measurements had high correlation (r = 0.98 and r = 0.81, respectively; P < .05 for both). Integrated kinetic energy quantified at peak systole correlated well (r = 0.95, P < .05), while kinetic energy levels at early and late filling showed no correlation. Flow component analysis showed high correlation for the direct and residual components, respectively (r = 0.93, P < .05 and r = 0.87, P < .05), while the retained and delayed components showed no correlation.ConclusionFour-dimensional flow CT produced qualitatively and quantitatively similar intracardiac blood flow patterns compared with the current reference standard, four-dimensional flow MRI.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-10 of 11
Type of publication
journal article (9)
conference paper (2)
Type of content
peer-reviewed (9)
other academic/artistic (2)
Author/Editor
Ebbers, Tino (8)
Henriksson, Lilian (8)
Lantz, Jonas (6)
Bäck, Sophia (6)
show more...
Karlsson, Matts (4)
Gupta, Vikas (4)
Karlsson, Lars (3)
Skoda, Iulia (3)
Lantz, Jonas, 1982- (3)
Karlsson, Matts, 196 ... (2)
Persson, Anders, 195 ... (2)
Ebbers, Tino, 1972- (2)
Carlhäll, Carljohan, ... (2)
Börjesson, Mats, 196 ... (1)
Engström, Gunnar (1)
Chew, Michelle (1)
Angerås, Oskar, 1976 (1)
Lind, Lars (1)
Redfors, Björn (1)
Persson, Margaretha (1)
Engvall, Jan (1)
Persson, Jonas (1)
Ostenfeld, Ellen (1)
Jernberg, Tomas (1)
Jujic, Amra (1)
Wennberg, Patrik, 19 ... (1)
Öhlin, Jerry (1)
Carlhäll, Carl-Johan ... (1)
Ekblom, Örjan, 1971- (1)
Mannila, Maria (1)
Ekblom Bak, Elin, 19 ... (1)
Flinck, Agneta (1)
Kero, Tanja (1)
Berntsson, Caroline (1)
Östgren, Carl Johan (1)
Fagman, Erika (1)
Sandberg, Camilla (1)
Bergman, Frida, Medi ... (1)
Bolger, Ann F (1)
Hedman, Kristofer (1)
Johansson, Peter, 19 ... (1)
Bolger, Ann F, 1957- (1)
Carlhäll, Carl Johan (1)
Dahlström, Nils (1)
Ohlsson, Linus (1)
Da Luz Moreira, Andr ... (1)
show less...
University
Linköping University (11)
University of Gothenburg (1)
Umeå University (1)
Uppsala University (1)
Lund University (1)
The Swedish School of Sport and Health Sciences (1)
show more...
Karolinska Institutet (1)
show less...
Language
English (11)
Research subject (UKÄ/SCB)
Engineering and Technology (6)
Medical and Health Sciences (5)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view